RFPFF exit exam questions and answer quiz contain questions Answer
If you find any questions incorrect, please let us know by Clicking here.
1. DCP Fixed Fire Fighting System is used in
which type of vessel
A) Oil Tankers
B) Chemical Tankers
C) Bulk carriers
D) Gas carrier
2. Maximum
Temperature of unexposed side of a B-class division is?
A) 300 Deg C
B) 350 Deg C
C) 400 Deg C
D) 225 Deg C
3. Class B Bulkheads
are classified as B15/B0
A) True
B) False
4. Dry chemical
powder extinguisher works on?
A) Smothering
B) Starvation
C) Inhibition
D) Cooling
5. How many hours diesel driven fire pump should
run?
A) 12 Hrs.
B) 14 Hrs.
C) 16 Hrs.
D) 18 Hrs.
6. Color of light
used for small boats?
A) Green
B) Yellow
C) White
D) Blue
7. Fire extinguishing
system required for propelling machines and diesel driven motor?
A) Hyper Mist
B) CO2
C) DCP
D) FOAM
8. Minimum capacity
of emergency fire pump?
A) 15 M3/Hr.
B) 20 M3/Hr.
C) 25 M3/Hr.
D) 30 M3/Hr.
9. Which
extinguishing agent is recommended in the chemical data for use on a carbon
disulfide fire?
A) Alcohol foam
B) Chemical foam
C) Dry chemical
D) Water fog
10. The components of a fire tetrahedron are oxygen, heat, fuel and chemical reaction
A) True
B) False
11. Extinguisher that
can be used for class - F/K fires
A) CO2
B) DCP
C) FOAM
D) WET CHEMICAL
12. Fire is a process
of combustion accompanied by the rapid release of heat and
A) Light
B) Energy
C) Destruction
D) None of these
13. The lowest
temperature at which the vapor of a flammable liquid will ignite and cause
self-sustained combustion in the presence of a spark or flame is the
A) Auto ignition temperature
B) Vaporization temperature
C) Flash point
D) Fire Point
14. Wood plastic and
paper are classified as
A) Class A fire
B) Class B fire
C) Class C fire
D) Class D fire
15. Metal fire is
extinguished using
A) CO2 extinguisher
B) Foam extinguisher
C) Water extinguisher
D) Dry powder
extinguisher
16. What is the length of a Fire Proof Line of SCBA?
A) 10 mtrs
B) 15 mtrs
C) 20 mtrs
D) 30 mtrs
17. What manoeuvre to be carried out in case of fire onboard?
A) Let the ship follow the wind in order to reduce the oxygen supply
B) Let the stem be up against the wind if possible
C) Continue on course and speed
D) Reduce speed and if possible, keep the Fire Zone on leeward side
18. Which of the following are frequent causes of fire in accommodation?
A) Overloading
B) Smoking in bed
C) Covering of electrical fires with blankets
D) All of the above
19. If there is an
isolated fire on the poop deck where should the master take control from
A) The Bridge
B) The emergency headquarters
C) The ship's office
D) On deck
20. When is the risk
of fire greatest?
A) When the vessel is in hot dry climate
B) When the vessel is in dense traffic situations
C) When the vessel is
in port, specially Dry-Dock
D) When the vessel is at sea in stormy weather
21. Minimum Capacity
of Emergency Fire Pumps?
A) 15 M3/Hr
B) 20 M3/Hr
C) 25 M3/Hr-
D) 30 M3/Hr
22. Color of Light
used for small boats?
A) Green
B) Yellow
C) White •
D) Blue
23. Fire Extinguishing
System required for propelling machines and diesel driven motor?
A) Hyper Mist •
B) CO2
C) DCP
D) Foam
24. Dry Chemical
Powder extinguisher works on?
A) Smothering
B) Starvation
C) Inhibition.
D) Cooling
25. CLASS-B Bulk heads are classified as B15/B0
A) True .
B) False
26. Maximum Temperature
of unexposed side ofa B-Class division is?
A) 300 Deg C
B) 350 Deg C
C) 400 Deg C
D) 225 Deg C.
27. DCP Fixed Fire Fighting
system is used in which type of vessel
Q Oil Tankers
Chemical Tankers
Bulk Carriers
Gas Carriers •
28. What is the
maximum weight of a Portable Fire Extinguisher?
A) 16 Kgs
B) 25 Kgs
C) 12 Kgs
D) 23 Kgs.
29. CLASS-A fire
extinguisher is best used on?
A) Solids
B) Liquids
C) Gas
D) Metals
30. Automatic CO2 release system is for which space?
A) Accommodation
B) Main Deck
C) Engine Room
D) None of the above